{"product_id":"aike-20-ultrapure-pure-water-system","title":"AIKE Advanced-20 Laboratory Ultrapure \u0026 Pure Water System, 20 L\/hr, 18.25 MΩ, Precision Research Grade (Model 20)","description":"\u003cdiv class=\"sc-lab-product-pipette\" style=\"font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,Helvetica,Arial,sans-serif;color:#0F172A;\"\u003e\n\u003cdiv style=\"margin-bottom:20px;\"\u003e\n\u003ch3 style=\"color:#0A2540;font-size:22px;font-weight:700;margin:0 0 10px;line-height:1.3;\"\u003eAIKE Advanced-20 Laboratory Ultrapure \u0026amp; Pure Water System, 20 L\/hr, 18.25 MΩ, Precision Research Grade (Model 20)\u003c\/h3\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:8px;margin-bottom:16px;\"\u003e\n\u003cspan style=\"background:#E6FFFA;color:#0D9488;font-size:12px;font-weight:600;padding:4px 10px;border-radius:4px;border:1px solid #99F6E4;\"\u003eISO 9001 \/ CE Certified\u003c\/span\u003e\n\u003cspan style=\"background:#EFF6FF;color:#1E40AF;font-size:12px;font-weight:600;padding:4px 10px;border-radius:4px;border:1px solid #BFDBFE;\"\u003eResearch \u0026amp; Clinical Grade\u003c\/span\u003e\n\u003cspan style=\"background:#F1F5F9;color:#475569;font-size:12px;font-weight:600;padding:4px 10px;border-radius:4px;border:1px solid #CBD5E1;\"\u003e18.25 MΩ·cm @ 25°C\u003c\/span\u003e\n\u003cspan style=\"background:#F8FAFC;color:#0F172A;font-size:12px;font-weight:600;padding:4px 10px;border-radius:4px;border:1px solid #E2E8F0;\"\u003eFactory-Direct Precision\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch4 style=\"color:#0A2540;font-size:16px;font-weight:700;margin:0 0 12px;border-bottom:2px solid #0D9488;padding-bottom:6px;display:inline-block;\"\u003eKey Features \u0026amp; Operational Benefits\u003c\/h4\u003e\n\u003cul style=\"list-style:none;padding:0;margin:0 0 16px;\"\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eDual Water Output (Type I \u0026amp; Type III):\u003c\/strong\u003e Simultaneously dispenses 18.25 MΩ·cm ultrapure water (UP) for molecular biology and analytical chemistry, alongside purified RO water for glassware washing and autoclave feeds.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eUltra-Low TOC \u0026amp; Pyrogen Free:\u003c\/strong\u003e Integrated 185\/254nm dual-wavelength UV photo-oxidation and ultrafiltration (UF) cartridge achieve Total Organic Carbon TOC \u0026lt; 3 ppb, Endotoxin \u0026lt; 0.001 EU\/mL, and RNase\/DNase-free specifications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eIntelligent Multi-Channel Monitoring:\u003c\/strong\u003e 3-channel NIST-traceable digital resistivity and conductivity cells continuously monitor feed water, RO water, and final ultrapure effluent with automatic temperature compensation (±0.1°C).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eAutomated Recirculation \u0026amp; RO Flushing:\u003c\/strong\u003e Automated periodic recirculation prevents bacterial biofilm incubation during standby periods, paired with scheduled reverse osmosis membrane pulse flushing to extend consumable longevity by over 20%.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eModular Quick-Connect Architecture:\u003c\/strong\u003e Tool-free quick-release cartridge bay allows single-operator maintenance in under 3 minutes with zero risk of plumbing cross-contamination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"sc-component-anatomy\" style=\"margin-bottom:28px;padding:20px;background:#F8FAFC;border:1px solid #E2E8F0;border-radius:8px;\"\u003e\n\u003cdiv style=\"display:flex;justify-content:space-between;align-items:center;margin-bottom:12px;flex-wrap:wrap;gap:8px;\"\u003e\n\u003ch4 style=\"color:#0A2540;font-size:15px;font-weight:700;margin:0;\"\u003eAuthentic Purification Flow \u0026amp; Engineering Architecture\u003c\/h4\u003e\n\u003cspan style=\"font-size:11px;font-family:monospace;background:#0A2540;color:#FFFFFF;padding:3px 8px;border-radius:3px;\"\u003eAIKE ELITE PURIFICATION PLATFORM\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align:center;margin:16px 0;background:#000000;border-radius:6px;padding:12px;overflow:hidden;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1012\/4754\/9720\/files\/aike-advanced-20-purification-flow.png?v=1795234412\" alt=\"AIKE Advanced-20 Laboratory Ultrapure Water System Engineering Purification Flow Diagram\" style=\"max-width:100%;height:auto;border-radius:4px;display:block;margin:0 auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit, minmax(220px, 1fr));gap:12px;margin-top:16px;\"\u003e\n\u003cdiv style=\"padding:12px;background:#FFFFFF;border:1px solid #E2E8F0;border-radius:6px;\"\u003e\n\u003cstrong style=\"color:#0A2540;font-size:12px;display:block;margin-bottom:4px;\"\u003e1. Pre-Treatment Multi-Filter\u003c\/strong\u003e\n\u003cspan style=\"font-size:11px;color:#475569;line-height:1.4;display:block;\"\u003eGraded 5μm PP sediment filter + dual granular and activated carbon canisters remove particulates, chlorine, and colloids.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:12px;background:#FFFFFF;border:1px solid #E2E8F0;border-radius:6px;\"\u003e\n\u003cstrong style=\"color:#0A2540;font-size:12px;display:block;margin-bottom:4px;\"\u003e2. Dual-Stage RO Reverse Osmosis\u003c\/strong\u003e\n\u003cspan style=\"font-size:11px;color:#475569;line-height:1.4;display:block;\"\u003ePrimary and secondary high-rejection RO modules eliminate \u0026gt;98% inorganic ions, silica, and heavy metal contaminants.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:12px;background:#FFFFFF;border:1px solid #E2E8F0;border-radius:6px;\"\u003e\n\u003cstrong style=\"color:#0A2540;font-size:12px;display:block;margin-bottom:4px;\"\u003e3. 185\/254nm Dual UV Photolysis\u003c\/strong\u003e\n\u003cspan style=\"font-size:11px;color:#475569;line-height:1.4;display:block;\"\u003eHigh-output quartz UV reactor oxidizes trace organics (TOC \u0026lt; 3 ppb) and ruptures microbial DNA.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:12px;background:#FFFFFF;border:1px solid #E2E8F0;border-radius:6px;\"\u003e\n\u003cstrong style=\"color:#0A2540;font-size:12px;display:block;margin-bottom:4px;\"\u003e4. Polishing DI Resin \u0026amp; UF Membrane\u003c\/strong\u003e\n\u003cspan style=\"font-size:11px;color:#475569;line-height:1.4;display:block;\"\u003eNuclear-grade ion-exchange resin reaches 18.25 MΩ·cm with 5000 Dalton UF membrane removing pyrogens and nucleases.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch4 style=\"color:#0A2540;font-size:16px;font-weight:700;margin:0 0 12px;border-bottom:2px solid #0A2540;padding-bottom:6px;display:inline-block;\"\u003eTechnical Specifications (Pipette.com Scientific Standard)\u003c\/h4\u003e\n\u003cdiv style=\"border:1px solid #E2E8F0;border-radius:6px;overflow:hidden;box-shadow:0 1px 3px rgba(0,0,0,0.05);\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;text-align:left;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eAIKE (Chengdu Tang's Corning Technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eModel \/ Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eAdvanced-20 (Model 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eUltrapure Water Resistivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e18.25 MΩ·cm @ 25°C (Conductivity \u0026lt; 0.055 µS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eRO Pure Water Conductivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e0 - 15 µS\/cm @ 25°C (Rejection rate \u0026gt; 98%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eProduction Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e20 Liters \/ Hour (Dispense Flow: 1.5 - 2.0 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eTotal Organic Carbon (TOC)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e\u0026lt; 3 ppb (Trace organic and HPLC \/ LC-MS grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003ePyrogens \/ Endotoxins\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e\u0026lt; 0.001 EU\/mL (Cell culture \u0026amp; IVF certified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eMicroorganisms \/ Bacteria\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e\u0026lt; 0.1 CFU\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eRNases \/ DNases\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eRNases \u0026lt; 0.08 ng\/mL; DNases \u0026lt; 12 pg\/mL (PCR \/ qPCR grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e420 × 410 × 560 mm (Benchtop \/ Wall-mountable); 28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003ePower \u0026amp; Operating Noise\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e100-240V AC, 50\/60 Hz; Silent diaphragm booster pump \u0026lt; 30 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eCompliance Standards\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eGB\/T6682-2008 Grade I, ASTM D1193 Type I, CAP \/ CLSI, EP, USP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom:20px;padding:16px;background:#F8FAFC;border:1px solid #E2E8F0;border-radius:6px;\"\u003e\n\u003ch4 style=\"color:#0A2540;font-size:14px;font-weight:700;margin:0 0 8px;\"\u003eWhat's in the Box (Complete Laboratory Kit)\u003c\/h4\u003e\n\u003cul style=\"list-style:none;padding:0;margin:0;\"\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × AIKE Advanced-20 Laboratory Ultrapure Water System Console\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × High-Resolution Backlit Multi-Parameter LCD Control Panel\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Pre-Treatment Unit (PP Sediment Cartridge + Dual Activated Carbon Filters)\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Dual-Stage Reverse Osmosis (RO) Membrane Assembly\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Nuclear-Grade High-Capacity DI Polishing Column Pair\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Dual-Wavelength UV Oxidation Reactor (185\/254 nm)\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Terminal 0.22 µm PES Capsule Dispense Filter\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × 30L Vacuum-Sealed Pure Water Pressure Tank with Dispense Tubing Kit\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Infrared Multifunctional Remote Controller, Power Supply \u0026amp; Factory Calibration Certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:14px 18px;background:#EFF6FF;border-left:4px solid #3B82F6;border-radius:0 6px 6px 0;margin-bottom:20px;\"\u003e\n\u003cstrong style=\"color:#1E3A8A;font-size:13px;display:block;margin-bottom:4px;\"\u003eInstitutional Procurement \u0026amp; Request for Quote (RFQ)\u003c\/strong\u003e\n\u003cspan style=\"color:#1E40AF;font-size:12px;line-height:1.5;\"\u003eSciClouds accepts formal Purchase Orders (PO) from universities, hospitals, research institutes, and biotech companies. Net 30 invoicing terms, dedicated cold-chain freight, and factory-authorized technical support are included.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AIKE","offers":[{"title":"Standard","offer_id":53372874031384,"sku":"20","price":399.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1012\/4754\/9720\/files\/aike-advanced-20-front.png?v=1795234411","url":"https:\/\/sciclouds.com\/fr\/products\/aike-20-ultrapure-pure-water-system","provider":"SOLISENSE","version":"1.0","type":"link"}