{"product_id":"clinx-liuyi-gelview-5000-gel-imaging-system","title":"Gel Imaging System, GelView 5000, CCD\u0026#8805;200 \/, Precision Research Grade (Model GelView 5000)","description":"\u003cdiv class=\"sc-lab-product-pipette\" style=\"font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,Helvetica,Arial,sans-serif;color:#0F172A;\"\u003e\n\u003cdiv style=\"margin-bottom:20px;\"\u003e\n\u003ch3 style=\"color:#0A2540;font-size:22px;font-weight:700;margin:0 0 10px;line-height:1.3;\"\u003eGel Imaging System, GelView 5000, CCD≥200 \/, Precision Research Grade (Model GelView 5000)\u003c\/h3\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:8px;margin-bottom:16px;\"\u003e\n\u003cspan style=\"background:#E6FFFA;color:#0D9488;font-size:12px;font-weight:600;padding:4px 10px;border-radius:4px;border:1px solid #99F6E4;\"\u003eISO 9001 \/ CE Certified\u003c\/span\u003e\u003cspan style=\"background:#EFF6FF;color:#1E40AF;font-size:12px;font-weight:600;padding:4px 10px;border-radius:4px;border:1px solid #BFDBFE;\"\u003eResearch \u0026amp; Clinical Grade\u003c\/span\u003e\u003cspan style=\"background:#F1F5F9;color:#475569;font-size:12px;font-weight:600;padding:4px 10px;border-radius:4px;border:1px solid #CBD5E1;\"\u003eFactory-Direct Warranty\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch4 style=\"color:#0A2540;font-size:16px;font-weight:700;margin:0 0 12px;border-bottom:2px solid #0D9488;padding-bottom:6px;display:inline-block;\"\u003eKey Features \u0026amp; Operational Benefits\u003c\/h4\u003e\n\u003cul style=\"list-style:none;padding:0;margin:0 0 16px;\"\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eScientific-grade Peltier-cooled CCD camera (-40°C to -65°C below ambient) delivers ultra-low dark current and exceptional signal-to-noise ratio.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eHigh quantum efficiency (\u0026gt; 75%) and 16-bit dynamic range (65,536 grayscale levels) for precise quantitative Western blot and DNA densitometry.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eMotorized F\/0.80 high-aperture lens with automated focus and aperture control provides rapid exposure of faint chemiluminescent bands.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eIntegrated multi-wavelength excitation: Trans-UV (302 nm), Epi-White light, Trans-White plate, and optional Blue-light LED transilluminator.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;color:#0F172A;line-height:1.6;display:flex;align-items:baseline;\"\u003e\n\u003cspan style=\"color:#0D9488;margin-right:8px;font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eIntelligent acquisition software features one-click auto-exposure, lane\/band auto-detection, molecular weight calculation, and GLP-compliant audit trails.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"sc-component-anatomy\" style=\"margin:24px 0;padding:18px;background:#F8FAFC;border:1px solid #E2E8F0;border-radius:8px;\"\u003e\n  \u003ch4 style=\"color:#0A2540;font-size:16px;font-weight:700;margin:0 0 12px;border-bottom:2px solid #0D9488;padding-bottom:6px;display:inline-block;\"\u003eComponent Architecture \u0026amp; Operational Anatomy\u003c\/h4\u003e\n  \u003cdiv style=\"text-align:center;margin:14px 0;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1012\/4754\/9720\/files\/e530f59b_40a958c5-ecd7-4259-bd0c-8e4b0e343315.jpg?v=1794996553\" alt=\"Gel Imaging System, GelView 5000, CCD≥200 \/, Precision Research Grade (Model GelView 5000) - Component Architecture \u0026amp; Operational Breakdown\" style=\"max-width:100%;height:auto;border-radius:6px;border:1px solid #CBD5E1;box-shadow:0 2px 4px rgba(0,0,0,0.06);\"\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:13px;color:#475569;line-height:1.6;margin:10px 0 0;\"\u003ePrecision architectural diagram illustrating the internal core mechanics, dynamic balancing assembly, acoustic dampening enclosure, and high-reliability microprocessor control architecture.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom:24px;\"\u003e\n\u003ch4 style=\"color:#0A2540;font-size:16px;font-weight:700;margin:0 0 12px;border-bottom:2px solid #0A2540;padding-bottom:6px;display:inline-block;\"\u003eTechnical Specifications (Pipette.com Scientific Standard)\u003c\/h4\u003e\n\u003cdiv style=\"border:1px solid #E2E8F0;border-radius:6px;overflow:hidden;box-shadow:0 1px 3px rgba(0,0,0,0.05);\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;text-align:left;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eManufacturer \/ Brand\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eLIUYI BIOTECH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eCatalog Model \/ SKU\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eGelView 5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eCamera Sensor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eScientific Grade Deep-Cooled CCD (16-bit, 65,536 gray levels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eCooling Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003e-40°C to -65°C absolute cooling below ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eLens Specifications\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eMotorized F\/0.80 high-transmission zoom lens with software feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eSample Viewing Area\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eUp to 21 × 26 cm (Accommodates multiple standard gels or blots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eExcitation Light Sources\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eDual UV (302 nm), Epi-White LED, White light conversion plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eFilter Wheel Mechanism\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eMotorized 5-position or 6-position filter wheel with standard 590 nm filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eInterface \u0026amp; OS\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eHigh-speed USB 3.0, Windows 10\/11 Compatible Analysis Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #E2E8F0;background:#F8FAFC;\"\u003e\n\u003ctd style=\"padding:10px 12px;font-weight:600;width:35%;color:#475569;font-size:13px;border-right:1px solid #E2E8F0;\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;color:#0F172A;font-size:13px;\"\u003eISO 9001, CE Certified, 21 CFR Part 11 Audit Trail Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom:20px;padding:16px;background:#F8FAFC;border:1px solid #E2E8F0;border-radius:6px;\"\u003e\n\u003ch4 style=\"color:#0A2540;font-size:14px;font-weight:700;margin:0 0 8px;\"\u003eWhat's in the Box (Standard Package Contents)\u003c\/h4\u003e\n\n  \u003cdiv style=\"text-align:center;margin:14px 0;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1012\/4754\/9720\/files\/6043bd69_9b87f848-e500-428d-b2b4-c588cf2a44c9.jpg?v=1795004413\" alt=\"Gel Imaging System, GelView 5000, CCD≥200 \/, Precision Research Grade (Model GelView 5000) - Standard Package \u0026amp; Unboxing Accessories Layout\" style=\"max-width:100%;height:auto;border-radius:6px;border:1px solid #CBD5E1;box-shadow:0 2px 4px rgba(0,0,0,0.06);\"\u003e\n  \u003c\/div\u003e\n\n\u003cul style=\"list-style:none;padding:0;margin:0;\"\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × LIUYI BIOTECH GelView 5000 Darkroom Imaging Enclosure with Cooled CCD Camera\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × High-Transmission Motorized Lens \u0026amp; Standard Optical Filter\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Trans-UV Transilluminator with White Light Conversion Plate\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Comprehensive Image Analysis \u0026amp; Densitometry Software Package\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × USB 3.0 High-Speed Cable \u0026amp; Universal Power Supply\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px;color:#334155;font-size:13px;\"\u003e• 1 × Calibration Test Target \u0026amp; Operating Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:14px 18px;background:#EFF6FF;border-left:4px solid #3B82F6;border-radius:0 6px 6px 0;margin-bottom:20px;\"\u003e\n\u003cstrong style=\"color:#1E3A8A;font-size:13px;display:block;margin-bottom:4px;\"\u003eInstitutional Procurement \u0026amp; Request for Quote (RFQ)\u003c\/strong\u003e\u003cspan style=\"color:#1E40AF;font-size:12px;line-height:1.5;\"\u003eSciClouds accepts formal Purchase Orders (PO) from verified universities, hospitals, research institutions, and biotech enterprises. Net 30 payment terms and custom bulk logistics available upon inquiry.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"LIUYI BIOTECH","offers":[{"title":"Standard","offer_id":53372893364504,"sku":"GelView 5000","price":3750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1012\/4754\/9720\/files\/bioer_002_NP_As_9600_15548e8fde_jpg_gray_b6434555.png?v=1795228723","url":"https:\/\/sciclouds.com\/pt\/products\/clinx-liuyi-gelview-5000-gel-imaging-system","provider":"SOLISENSE","version":"1.0","type":"link"}